Resource StructureDefinition/FHIR Server from package nictiz.fhir.nl.stu3.zib2017#2.2.18 (125 ms)
Package | nictiz.fhir.nl.stu3.zib2017 |
Type | StructureDefinition |
Id | Id |
FHIR Version | R3 |
Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2017@2.2.18&canonical=http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine |
Url | http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine |
Version | 1.0.1 |
Status | active |
Name | Zib Infusion-LumenOrLine |
Title | HCIM Infusion-LumenOrLine |
Experimental | False |
Realm | nl |
Authority | hl7 |
Description | Lumen and/or line information about the infusion as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or zib) 'Infusion', modeled as a complex extension. |
Purpose | To provide information about the lumens and/or lines in an infusion. Currently, there is no field avaiblable in a DeviceUseStatement resource for this information, hence the reason for this extension. |
Copyright | CC0 |
Type | Extension |
Kind | complex-type |
Resources that use this resource
Resources that this resource uses
Source
{
"resourceType" : "StructureDefinition",
"id" : "zib-Infusion-LumenOrLine",
"url" : "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine",
"version" : "1.0.1",
"name" : "Zib Infusion-LumenOrLine",
"title" : "HCIM Infusion-LumenOrLine",
"status" : "active",
"publisher" : "Nictiz",
"contact" : [
{
"name" : "Nictiz",
"telecom" : [
{
"system" : "url",
"value" : "https://www.nictiz.nl",
"use" : "work"
}
]
}
],
"description" : "Lumen and/or line information about the infusion as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or zib) 'Infusion', modeled as a complex extension.",
"purpose" : "To provide information about the lumens and/or lines in an infusion. Currently, there is no field avaiblable in a DeviceUseStatement resource for this information, hence the reason for this extension.",
"copyright" : "CC0",
"fhirVersion" : "3.0.2",
"kind" : "complex-type",
"abstract" : false,
"contextType" : "resource",
"context" : [
"DeviceUseStatement"
],
"type" : "Extension",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Extension",
"path" : "Extension",
"short" : "LumenOrLine",
"definition" : "Container of the LumenOrLine concept. This container contains all data elements of the LumenOrLine concept.\r\n\r\nCentral lines can contain one or more lumens; peripheral infusions do not have lumens and only have one line.",
"alias" : [
"LumenOfLijn"
]
},
{
"id" : "Extension.extension",
"path" : "Extension.extension",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "url"
}
],
"rules" : "open"
}
},
{
"id" : "Extension.extension:LineStatus",
"path" : "Extension.extension",
"sliceName" : "LineStatus",
"short" : "LineStatus",
"definition" : "LineStatus is used to indicate whether it is a running infusion, whether it has been capped, or has been fitted with a heparin lock, etc.",
"alias" : [
"LijnStatus"
],
"max" : "1"
},
{
"id" : "Extension.extension:LineStatus.url",
"path" : "Extension.extension.url",
"fixedUri" : "LineStatus"
},
{
"id" : "Extension.extension:LineStatus.value[x]:valueCodeableConcept",
"path" : "Extension.extension.valueCodeableConcept",
"sliceName" : "valueCodeableConcept",
"type" : [
{
"code" : "CodeableConcept"
}
],
"binding" : {
"strength" : "preferred",
"description" : "LineStatusCodeList",
"valueSetReference" : {
"reference" : "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.2.3--20171231000000",
"display" : "LineStatusCodeList"
}
}
},
{
"id" : "Extension.extension:LumenLocation",
"path" : "Extension.extension",
"sliceName" : "LumenLocation",
"short" : "LumenLocation",
"definition" : "For central venous catheters with multiple lumens, LumenLocation indicates the relative position of the lumen with respect to the insertion opening.",
"alias" : [
"LumenLocatie"
],
"max" : "1"
},
{
"id" : "Extension.extension:LumenLocation.url",
"path" : "Extension.extension.url",
"fixedUri" : "LumenLocation"
},
{
"id" : "Extension.extension:LumenLocation.value[x]:valueCodeableConcept",
"path" : "Extension.extension.valueCodeableConcept",
"sliceName" : "valueCodeableConcept",
"type" : [
{
"code" : "CodeableConcept"
}
],
"binding" : {
"strength" : "preferred",
"description" : "LumenLocationCodeList",
"valueSetReference" : {
"reference" : "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.2.2--20171231000000",
"display" : "LumenLocationCodeList"
}
}
},
{
"id" : "Extension.extension:LockFluid",
"path" : "Extension.extension",
"sliceName" : "LockFluid",
"short" : "LockFluid",
"definition" : "The description of the fluid used as an anticoagulation lock, such as heparin.",
"alias" : [
"SlotVloeistof"
],
"max" : "1"
},
{
"id" : "Extension.extension:LockFluid.url",
"path" : "Extension.extension.url",
"fixedUri" : "LockFluid"
},
{
"id" : "Extension.extension:LockFluid.value[x]:valueReference",
"path" : "Extension.extension.valueReference",
"sliceName" : "valueReference",
"type" : [
{
"code" : "Reference",
"targetProfile" : "http://nictiz.nl/fhir/StructureDefinition/zib-MedicationAdministration"
}
]
},
{
"id" : "Extension.extension:AdministeringSystem",
"path" : "Extension.extension",
"sliceName" : "AdministeringSystem",
"short" : "AdministeringSystem",
"definition" : "The administering system contains the entire system making the fluid run from the infusion bag via the cannula/catheter to the patient. This also includes any three-way valves/connecting joints used.",
"alias" : [
"ToedieningsSysteem"
]
},
{
"id" : "Extension.extension:AdministeringSystem.url",
"path" : "Extension.extension.url",
"fixedUri" : "AdministeringSystem"
},
{
"id" : "Extension.extension:AdministeringSystem.value[x]:valueReference",
"path" : "Extension.extension.valueReference",
"sliceName" : "valueReference",
"type" : [
{
"code" : "Reference"
}
]
},
{
"id" : "Extension.url",
"path" : "Extension.url",
"fixedUri" : "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine"
},
{
"id" : "Extension.value[x]",
"path" : "Extension.value[x]",
"max" : "0",
"type" : [
{
"code" : "base64Binary"
},
{
"code" : "boolean"
},
{
"code" : "code"
},
{
"code" : "date"
},
{
"code" : "dateTime"
},
{
"code" : "decimal"
},
{
"code" : "id"
},
{
"code" : "instant"
},
{
"code" : "integer"
},
{
"code" : "markdown"
},
{
"code" : "oid"
},
{
"code" : "positiveInt"
},
{
"code" : "string"
},
{
"code" : "time"
},
{
"code" : "unsignedInt"
},
{
"code" : "uri"
},
{
"code" : "Address"
},
{
"code" : "Age"
},
{
"code" : "Annotation"
},
{
"code" : "Attachment"
},
{
"code" : "CodeableConcept"
},
{
"code" : "Coding"
},
{
"code" : "ContactPoint"
},
{
"code" : "Count"
},
{
"code" : "Distance"
},
{
"code" : "Duration"
},
{
"code" : "HumanName"
},
{
"code" : "Identifier"
},
{
"code" : "Money"
},
{
"code" : "Period"
},
{
"code" : "Quantity"
},
{
"code" : "Range"
},
{
"code" : "Ratio"
},
{
"code" : "Reference"
},
{
"code" : "SampledData"
},
{
"code" : "Signature"
},
{
"code" : "Timing"
},
{
"code" : "Reference",
"targetProfile" : "http://nictiz.nl/fhir/StructureDefinition/zib-MedicationAdministration"
}
]
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.